Troubleshooting; Confirming Whether There Is A Failure - Oracle Fujitsu SPARC M12-1 Service Manual

Table of Contents

Advertisement

Table 4-2     Combinations of Servers and MBU Types
Server
SPARC M12-1
Table 4-3
and FRU types.
Table 4-3     Correspondence Between Memory and Types
FRU
Memory
Note - The FRU type indicator may vary depending on the hardware configuration.
See the information about the hardware in the Fujitsu SPARC M12 Product Notes for the
latest XCP version.
4.2

Troubleshooting

This section describes suspected failure conditions. Use the flow to confirm whether
there is a failure and identify the failure location in the following cases. For details on
the flow for confirming whether there is a failure, see
There is a
When the CHECK LED is on
When an error message is displayed on the console
When an error is displayed as a result of executing a command for checking the
status
When an error is displayed in the error log
4.2.1

Confirming Whether There is a Failure

This section describes the flow for confirming whether there is a failure. Also apply
this flow to identify failures in the PCI expansion unit.
Fujitsu Product ID (Oracle Product ID)
SPNAAAA1xx (7118228), SPNAAAA2xx (7602945)
SPNAAAA3xx (7605161)
SPNAAAA4xx (7605940)
shows the correspondence between memory mounted in the SPARC M12-1
Type Indicator
Configuration
81
DDR4 R-DIMM 8 GB 1 Rank
83
DDR4 R-DIMM 16 GB 1 Rank
85
DDR4 R-DIMM 32 GB 2 Rank
87
DDR4 R-DIMM 64 GB 4 Rank
91
DDR4 R-DIMM 64 GB 2 Rank
Failure."
Chapter 4 Preparation and Precautions for Maintenance
MBU Type Indicator
C
F
G
"4.2.1 Confirming Whether
37

Advertisement

Table of Contents
loading

Table of Contents