Oracle Fujitsu SPARC M12-1 Service Manual page 126

Table of Contents

Advertisement

System-stopped/cold addition
System-stopped/cold addition can be performed on a PCIe card and HDD/SSD.
Perform the following procedure to add the unit.
Figure 7-10     System-Stopped/Cold Addition Flow
1. Opening the rack door
2. Switching the mode switch on the operation
panel to Service mode
3. Checking the operating condition of the
system and the I/O device usage status
4. Stopping the system
5. Removing the power cords
6. Installing the target FRU
7. Installing the power cords
8. Performing a diagnosis test
9. Confirming that there is no problem with the
installed FRU
10. Returning the mode switch on the operation
11. Starting the system
12. Closing the rack door
112
Fujitsu SPARC M12-1 Service Manual • January 2023
panel to Locked mode
Addition complete