6.3.1

Setting the Time

Confirm that the XSCF STANDBY LED on the operation panel is on.
1.
Log in to the XSCF shell.
2.
Execute the showdate command to display the XSCF time.
3.
In the following example, the current local time is displayed.
XSCF> showdate
Mon Jan 1 09:17:24 JST 2001
Execute the setdate command to set the XSCF time.
4.
Specify the time in either of the following formats:
yyyy.MM.DD-hh:mm:ss
MMDDhhmmyyyy.ss
In the following example, "June 15, 2017 16:59:00" is specified.
XSCF> setdate -s 061516592017.00
6.3.2

Confirming the Firmware Version

1.
Log in to the XSCF shell.
2.
Execute the version command to confirm the firmware version information.
If the XCP firmware version does not match that used before the replacement,
update the firmware.
For details, see "16.5 Updating Firmware" in the Fujitsu SPARC M12 and Fujitsu
M10/SPARC M10 System Operation and Administration Guide.
XSCF> version -c xcp -v
BB#00-XSCF#0 (Master)
XCP0 (Reserve): 3025
XSCF
XCP1 (Current): 3025
XSCF
CMU
CMU BACKUP
#0: 03.02.0005
#1: ..
XSCF>
82
Fujitsu SPARC M12-1 Service Manual • January 2023
 
: 03.02.0005
: 03.02.0005
: 03.02.0005
POST
: 5.15.0
OpenBoot PROM : 4.38.5+3.1.0
Hypervisor
: 1.5.13
year.month.day-hour (24-hour clock):minute:second
monthdayhour (24-hour clock) minuteyear.second