Oracle Fujitsu SPARC M12-1 Service Manual page 67

Table of Contents

Advertisement

system, you can normally check on the system console for messages regarding a disk
that is likely to fail or that has already failed. This information is also recorded in the
/var/adm/messages file.
In these error messages, a failed internal disk drive is normally indicated with a
physical device name or logical device name. In addition, depending on the
application, the slot number of the HDD/SSD may be reported.
The procedure to check information on HDD/SSD mounting locations varies
depending on the operating system.
For Oracle Solaris 11
For details, see
diskinfo command (Oracle Solaris
For Oracle Solaris 10
For details, see
Using the format command (Oracle Solaris 11)
Execute the format command to check the HDD/SSD slots.
1.
(1) to (4) in the following example represent:
(1): Logical path name of the disk
(2): The disk is mounted in the HDD#0 slot
(3): The disk is mounted in the HDD#1 slot
(4): The disk is mounted in the HDD#2 slot
# format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c2t50000393B81B3A36d0 <TOSHIBA-MBF2600RC-3706 cyl 46873 alt 2 hd 20
sec 625> <-- (1)
/pci@8100/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@w50000393b81b3a36,0
/dev/chassis/SYS/HDD00/disk <-- (2)
1. c2t500000E01FB332A2d0 <FUJITSU-MBD2600RC-3701 cyl 46873 alt 2 hd 20
sec 625> <-- (1)
/pci@8100/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@w500000e01fb332a2,0
/dev/chassis/SYS/HDD01/disk <-- (3)
2. c2t50000393B81B4D7Ad0 <TOSHIBA-MBF2600RC-3706 cyl 46873 alt 2 hd 20
sec 625> <-- (1)
/pci@8100/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@w50000393b81b4d7a,0
/dev/chassis/SYS/HDD02/disk <-- (4)
Specify disk (enter its number):
Using the diskinfo command (Oracle Solaris 11)
1.
Execute the diskinfo command to check the HDD/SSD slots.
(1) to (3) in the following example represent:
(1): Device path name and logical path name of the disk mounted in HDD#0
(2): Device path name and logical path name of the disk mounted in HDD#1
"Using the format command (Oracle Solaris
11)."
"Using the diskinfo command (Oracle Solaris
Chapter 5 Preparations Required for Maintenance
11)" or
"Using the
10)."