Class properties [FIBRECHANNEL]
port-wwn = 10:00:00:14:4f:f8:38:99
node-wwn = 20:00:00:14:4f:f8:38:99
bw-percent = 0
:
/SYS/PCI1/IOVNET.PF0.VF0
[pci@8200/pci@4/pci@0/pci@8/network@0,80]
Class properties [NETWORK]
mac-addr = 00:14:4f:f8:b2:73
mtu = 1500
:
6.
Stop the logical domains and put them in the OpenBoot PROM state.
Before powering off the system, follow the appropriate procedure to stop the
logical domains, and execute the ldm unbind command to place them in the
inactive state.
primary# shutdown -i0 -g0 -y
Execute the printenv command to confirm the OpenBoot PROM environment
7.
variables, and save the output data.
If there is any item omitted with "...", check the item again.
{0} ok printenv boot-device
boot-device = /pci@8100/pci@4/pci@0/pci@0/scsi@0/disk@p0,0
5.7
Releasing a FRU From the System
With the replacefru Command
This section describes the procedure for releasing a FRU requiring maintenance from
the system. The following FRUs can be maintained.
PSU
■
FANU
■
Note - If the XSCF startup mode is high-speed mode, hardware cannot be replaced using the
replacefru command. Replace hardware with the input power turned off.
1.
Log in to the XSCF shell.
Execute the replacefru command to display the maintenance menu.
2.
XSCF> replacefru
60
Fujitsu SPARC M12-1 Service Manual • January 2023
VF
PCIE1
XXXXX
Need help?