XSCF> showlogs error
Date: Oct 20 12:45:31 JST 2012
Code: 00112233-445566778899aabbcc-8899aabbcceeff0011223344
Status: Alarm
FRU: /PSU#1
Msg: ACFAIL occurred (ACS=3)(FEP type = A1)
Date: Oct 20 15:45:31 JST 2012
Code: 00112233-445566778899aabbcc-8899aabbcceeff0011223344
Status: Warning
FRU: /PSU#1
Msg: ACFAIL occurred (ACS=3)(FEP type = A1)
Table 4-5
Table 4-5     Operands of the showlogs Command and Displayed Logs
Operand
error
event
power
env
monitor
console
ipl
panic
Checking the messages output by the predictive self-repairing
tool
Check the messages output from the Oracle Solaris Fault Manager predictive
self-repairing tool, running on Oracle Solaris. Oracle Solaris Fault Manager supports
the following functions:
Receives telemetry information about errors.
Performs troubleshooting.
Disables the FRU where an error occurred.
Turns on the LED of the FRU where an error occurred and displays details in a
system console message.
Table 4-6
indicate that the fault has already been diagnosed. If corrective actions can be taken
by the system, this indicates that they have already been taken. In addition, if the
system is running, corrective actions continue to be applied.
Messages are displayed on the console and are recorded in the /var/adm/messages
file.
42
Fujitsu SPARC M12-1 Service Manual • January 2023
Occurred: Oct 20 12:45:31.000 JST 2012
Occurred: Oct 20 15:45:31.000 JST 2012
shows operands of the showlogs command and the log to be displayed.
Description
Lists the error log.
Lists the event log.
Lists the power log.
Lists the temperature history.
Lists the monitoring message log.
Lists the console message log.
Lists the IPL message log.
Lists the panic message log.
lists typical messages generated at error occurrence. These messages