# cfgadm -al
Ap_Id
Condition
<Omitted>
c2
unknown
c2::dsk/c2t50000394281B50C6d0 disk
unknown
c2::es/ses0
unknown
c2::smp/expd0
unknown
c3
unknown
c4
unknown
c5
unknown
c6
unknown
c7
unknown
<Omitted>
4.
If the system does not recognize the incorporated HDD/SSD, make it
recognized in the system.
a. Execute the cfgadm -c configure command to incorporate the target HDD/SSD
into the logical domain.
# cfgadm -c configure Ap_Id
b. With the cfgadm -al command, check the status of the HDD/SSD.
5.
If the CHECK LED on the mounted HDD/SSD is not off, execute the cfgadm -x
command to turn off the CHECK LED on that HDD/SSD.
# cfgadm -x led=fault,mode=off Ap_Id
If you enabled the hotplug service, execute the svcadm disable command to
6.
disable the hotplug service.
# svcadm disable hotplug
Assign the I/O device of the incorporated HDD/SSD to the logical domain.
7.
To configure the hardware RAID by adding a new HDD/SSD, see "14.2
Configuring Hardware RAID" in the Fujitsu SPARC M12 and Fujitsu M10/SPARC
M10 System Operation and Administration Guide.
Chapter 6 Understanding the Preparations for Restoring the System
Type
Receptacle Occupant
scsi-sas
connected configured
connected configured
ESI
connected configured
smp
connected configured
scsi-sas
connected unconfigured
scsi-sas
connected unconfigured
fc
connected unconfigured
fc
connected unconfigured
scsi-sas
connected unconfigured