-v: Additionally displays a detailed message from the initial diagnosis.
-p: During diagnosis processing, executes the "probe-scsi-all" command of the
OpenBoot PROM and displays the result.
-s: During diagnosis processing, executes the "show-devs" command of the
OpenBoot PROM and displays the result.
-a: Diagnoses all the mounted PSBs.
XSCF> testsb -v -p -s -a -y
Initial diagnosis is about to start, Continue?[y|n] : y
PSB power on sequence started.
POST Sequence 01 Banner
:
 
<<Displayed execution results of "probe-scsi-all">>
/pci@8100/pci@4/pci@0/pci@0/scsi@0
 
FCode Version 1.00.56, MPT Version 2.00, Firmware Version 20.00.10.00
 
Target a
Unit 0
Disk
SASDeviceName 500003970830e04d
Target b
Unit 0
Encl Serv device
SASAddress 500000e0e0d0097d
:
 
<<Displayed execution results of "show-devs">>
/pci@8300/pci@4
/pci@8300/pci@4/pci@0
/pci@8300/pci@4/pci@0/pci@1
/pci@8200/pci@4
/pci@8200/pci@4/pci@0
/pci@8200/pci@4/pci@0/pci@8
/pci@8200/pci@4/pci@0/pci@0
/pci@8200/pci@4/pci@0/pci@0/network@0,1
/pci@8200/pci@4/pci@0/pci@0/network@0
:
PSB
Test
Fault
---- ------- --------
00-0 Passed
Normal
3.
From the execution result of "probe-scsi-all", confirm that the mounted
HDDs/SSDs are recognized.
4.
From the execution result of "show-devs", confirm that the mounted PCIe
cards are recognized.
From the execution result of the initial diagnosis, confirm that "Passed" and
5.
"Normal" are displayed for all the PSBs.
84
Fujitsu SPARC M12-1 Service Manual • January 2023
TOSHIBA
AL13SEB600AL14SE 3702
SASAddress 500003970830e04e
FUJITSU
PhyNum 14
1172123568 Blocks, 600 GB
NBBEXP
1303
PhyNum 0