Oracle Fujitsu SPARC M12-1 Service Manual page 75

Table of Contents

Advertisement

With a number key, select the FRU requiring maintenance.
3.
In the following example, since the FANU is selected, "1" is entered.
------------------------------------------------------------------------------
Maintenance/Replacement Menu
Please select a type of model which has FRU to be replaced.
 
1. FAN
(Fan Unit)
2. PSU
(Power Supply Unit)
------------------------------------------------------------------------------
Select [1,2|c:cancel] : 1
With a number key, select the FRU requiring maintenance.
4.
In the following example, since FAN#6 is showing "Faulted" indicating an error,
"7" is entered.
------------------------------------------------------------------------------
Maintenance/Replacement Menu
Please select a FRU to be replaced.
 
No. FRU
--- ------------------- --------------
1
/FAN#0
2
/FAN#1
3
/FAN#2
4
/FAN#3
5
/FAN#4
6
/FAN#5
7
/FAN#6
------------------------------------------------------------------------------
Select [1-7|b:back] : 7
5.
After confirming that the selected FRU is displayed, enter [r].
You are about to replace FAN#6.
Do you want to continue?[r:replace|c:cancel] : r
Confirm that the CHECK LED of the FRU is blinking.
6.
For the location of the CHECK LED, see
Please execute the following steps:
1) Confirm the Check LED is blinking.
2) Remove FAN#6.
3) Execute either the following:
3-1) After installing the exchanged device, please select 'finish'.
3-2) If you want to suspend the maintenance without exchanging device,
please select 'cancel'.
[f:finish|c:cancel] :
You can now start FRU maintenance. Do not enter "f" until you complete the
Status
Normal
Normal
Normal
Normal
Normal
Normal
Faulted
"2.4.3 LEDs on Each
Chapter 5 Preparations Required for Maintenance
Component."