5.4.2

Releasing an HDD/SSD From the System

To use the hot plug function, the hotplug service of Oracle Solaris needs to be
enabled. Check the status of the service. If it is disabled, enable the hotplug service in
the following procedure. The hot plug function is available only on the control
domain and root domain.
Note - Unless the system has a redundant configuration, the data on the HDD/SSD will be
lost. Thus, perform this operation only after backing up the data in advance. In addition,
active/hot maintenance of the boot device in a non-redundant configuration cannot be
performed.
# svcs hotplug ← If the STATE is disabled, enable the service.
# svcadm enable hotplug ← Enables the hotplug service.
For details on the cfgadm command used here, see "Chapter 2 Dynamically
Configuring Devices" in the Managing Devices in Oracle Solaris 11.2 or "Dynamically
Configuring Devices (Tasks)" in the Oracle Solaris Administration: Devices and File
Systems.
Execute the cfgadm command to check the configuration of the internal storage.
1.
In HDD/SSD replacement or reduction, use the cfgadm -a command to check the
Ap_ID of the disk requiring maintenance, and make a note of it. The Ap_ID
refers to a string such as "c4::dsk/c4t5000039428298FFEd0".
In HDD expansion, use the cfgadm -a command to check the number of disks
mounted.
# cfgadm -a
2.
Stop all applications from using the HDD/SSD.
3.
Execute the cfgadm command to release the HDD/SSD requiring maintenance
from the system.
Enter the Ap_ID you noted in advance.
# cfgadm -c unconfigure Ap_ID
4.
Execute the cfgadm command to confirm that the HDD/SSD requiring
maintenance is disconnected.
The disconnected HDD/SSD is displayed as "unconfigured."
# cfgadm -a
5.
Execute the cfgadm command to blink the CHECK LED of the HDD/SSD
requiring maintenance, and confirm its location.
Enter the Ap_ID you noted in advance.
Chapter 5 Preparations Required for Maintenance