Install the upper cover.
2.
For details, see
3.
Close the fan cover.
For details, see
4.
Put the SPARC M12-1 into the rack.
For details, see
Connect all the cables of the external interface.
5.
Note - Reinstall the cables in their original positions by referring to the record that you made
before the start of maintenance.
Disconnect the XSCF LAN cables, and connect the serial cable.
6.
7.
Connect the power cords of the SPARC M12-1 requiring maintenance at their
original positions.
Note - Reinstall the power cords in their original positions by referring to the record that you
made before the start of maintenance.
Note - The XSCF STANDBY LED (green) on the operation panel blinks when the power
cords are connected. As the LED blinks, wait a moment for it to stay on. This indicates that
XSCF initialization completed successfully.
Log in to the XSCF via the serial port.
8.
Set the XSCF time.
9.
For details on the procedure, see
10. Confirm that the XSCF reboots, and then connect the XSCF LAN cable.
Note - Reinstall the cables in their original positions by referring to the record that you made
before the start of maintenance.
11. Match the XCP firmware version with the pre-replacement version.
For details on the procedure, see
The FRU installation work is completed. See
continue maintenance work.
200
Fujitsu SPARC M12-1 Service Manual • January 2023
"6.1.3 Installing the Upper
"6.1.4 Closing the Fan
"6.1.5 Putting the SPARC M12-1 Into the
"6.3.1 Setting the
"6.3.2 Confirming the Firmware
Cover."
Cover."
Rack."
Time."
"Chapter 7 Maintenance
Version."