Oracle Fujitsu SPARC M12-1 Service Manual page 134

Table of Contents

Advertisement

System-stopped/cold removal
System-stopped/cold removal can be performed on a PCIe card and HDD/SSD.
Perform the following procedure to remove the unit.
Figure 7-14     System-Stopped/Cold Removal Flow
1. Opening the rack door
2. Switching the mode switch on the operation
panel to Service mode
3. Checking the operating condition of the
system and the I/O device usage status
4. Stopping the system
5. Removing the power cords
6. Removing the target FRU
7. Installing the power cords
8. Performing a diagnosis test
9. Confirming that there is no problem with the
chassis after the removal
10. Returning the mode switch on the operation
11. Starting the system
12. Closing the rack door
120
Fujitsu SPARC M12-1 Service Manual • January 2023
panel to Locked mode
Removal complete

Advertisement

Table of Contents
loading

Table of Contents