Encoder Module Settings - ABB ACS880 Firmware Manual

Primary control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
90.63
Feed constant
numerator
-2147483648 ...
2147483647
90.64
Feed constant
denominator
-2147483648 ...
2147483647
91
91 Encoder module
settings
91.01
FEN DI status
Bit
Name
0
DI1 /module 1
1
DI2 /module 1
2...3
Reserved
4
DI1 /module 2
5
DI2 /module 2
6...15
Reserved
0000h...FFFFh
91.02
Module 1 status
91.03
Module 2 status
91.04
Module 1
temperature
0...1000 °C or °F
Description
Parameters
90.63
and
90.64
position calculation:
90.63 Feed constant numerator
90.64 Feed constant denominator
The feed constant converts rotational motion into translatory
motion. The feed constant is the distance the load moves
during one turn of the motor shaft.
The translatory load position is shown by parameter
Load position
scaled.
Feed constant numerator.
See parameter
90.63 Feed constant
Feed constant denominator.
Configuration of encoder interface modules.
Displays the status of the digital inputs of FEN-xx encoder
interface modules.
This parameter is read-only.
Information
DI1 of interface module 1 (see parameters
DI2 of interface module 1 (see parameters
DI1 of interface module 2 (see parameters
DI2 of interface module 2 (see parameters
Status word of digital inputs on FEN-xx modules.
Displays the type of the interface module found in the location
specified by parameter
91.12 Module 1
0 = No module found; 1 = No communication; 2 = Unknown;
3 = FEN-01; 4 = FEN-11; 5 = FEN-21; 6 = FEN-31.
This parameter is read-only.
Displays the type of the interface module found in the location
specified by parameter
91.14 Module 2
0 = No module found; 1 = No communication; 2 = Unknown;
3 = FEN-01; 4 = FEN-11; 5 = FEN-21; 6 = FEN-31.
This parameter is read-only.
Displays the temperature measured through the sensor input
of interface module 1. The unit is selected by parameter
96.16 Unit
selection.
This parameter is read-only.
Temperature measured through interface module 1.
define the feed constant for the
90.05
numerator.
91.11
91.11
91.13
91.13
location.
location.
Parameters 283
Def/FbEq16
1
-
1
-
-
and 91.12)
and 91.12)
and 91.14)
and 91.14)
1 = 1
-
-
-
-

Advertisement

Table of Contents
loading

Table of Contents