216 Parameters
No.
Name/Value
Other
35.20
Temperature 2
action
No action
Warning
Fault
35.21
Temperature 2
source
Disabled
Estimated
temperature
KTY84 StdIO /
Extension I/O
module
KTY84 encoder
module 1
KTY84 encoder
module 2
Description
Source selection (see
Terms and abbreviations
Defines the action taken by the drive when measured
temperature 2 (parameter 35.03) exceeds the appropriate
limits set by parameters
35.23 Temperature 2 warning
No action.
Warning
A492 External temperature 2
measured temperature 2 exceeds the limit set by parameter
35.23 Temperature 2 warning
Warning
A492 External temperature 2
measured temperature 2 exceeds the limit set by parameter
35.23 Temperature 2 warning
4982 External temperature 2
exceeds the limit set by parameter
limit.
If the fault limit is set lower than the warning limit, exceeding
the fault limit will both trip the drive and generate a warning.
Selects the source from which measured temperature 2 is
read.
Usually this source is from a sensor connected to the motor
controlled by the drive, but it could be used to measure and
monitor a temperature from other parts of the process as long
as a suitable sensor is used as per the selection list.
None. Temperature monitoring function 2 is disabled.
Estimated motor temperature (see parameter
estimated
temperature).
The temperature is estimated from an internal drive
calculation. It is important to set up the ambient temperature
of the motor in
35.50 Motor ambient
KTY84 sensor connected to the analog input selected by
parameter
35.24 Temperature 2 AI source
output. The analog input can be from the standard I/O or from
an extension module.
The following settings are required:
• Set the hardware jumper or switch related to the analog
input to U (voltage). Any change must be validated by a
control unit reboot.
• Set the appropriate analog input unit selection parameter
in group
12 Standard AI
• In parameter group
13 Standard
selection parameter of the analog output to
excitation".
The analog output feeds a constant current through the
sensor. As the resistance of the sensor increases along with
its temperature, the voltage over the sensor increases. The
voltage is read by the analog input and converted into
degrees.
KTY84 sensor connected to encoder interface 1.
See also parameters
91.21 Temperature meas sel1
91.22 Temperature filtering time
KTY84 sensor connected to encoder interface 2.
See also parameters
91.24 Temperature meas sel2
91.25 Temperature filtering time
on page 88).
35.22 Temperature 2 fault limit
limit.
is generated when
limit.
is generated when
limit. The drive trips on fault
when measured temperature 2
35.22 Temperature 2 fault
35.01 Motor
temperature.
and an analog
to
V
(volt).
AO, set the source
"Force KTY84
1.
2.
Def/FbEq16
-
No action
and
0
1
2
Disabled
0
1
2
3
and
4
and

Advertisement

Table of Contents
loading

Table of Contents