ABB ACS880 Firmware Manual page 97

Primary control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
06.18
Start inhibit status
word
Bit
Name
0
Not ready run
1
Ctrl location changed
2
SSW inhibit
3
Fault reset
4
Lost start enable
5
Lost run enable
6
FSO inhibit
7
STO
8
Current calibration
ended
9
ID run ended
10
Auto phase ended
11
Em Off1
12
Em Off2
13
Em Off3
14
Auto reset inhibit
15
Jogging active
0000h...FFFFh
06.19
Speed control
status word
Bit
Name
0
Zero speed
1
Forward
2
Reverse
3
Out of window
4
Internal speed feedback 1 = Estimated speed feedback used (see par. 90.41)
5
Encoder 1 feedback
6
Encoder 2 feedback
Any constant speed
7
request
8...15
Reserved
0000h...FFFFh
Description
Start inhibit status word. This word specifies the source of the
inhibiting signal that is preventing the drive from starting.
The conditions marked with an asterisk (*) only require that
the start command is cycled. In all other instances, the
inhibiting condition must be removed first.
See also parameter
06.16 Drive status word
This parameter is read-only.
Description
1 = DC voltage is missing or drive has not been parametrized
correctly. Check the parameters in groups 95 and 99.
* 1 = Control location has changed
1 = Control program is keeping itself in inhibited state
* 1 = A fault has been reset
1 = Start enable signal missing
1 = Run enable signal missing
1 = Operation prevented by FSO-xx safety functions module
1 = Safe torque off active
* 1 = Current calibration routine has finished
* 1 = Motor identification run has finished
* 1 = Autophasing routine has finished
1 = Emergency stop signal (mode off1)
1 = Emergency stop signal (mode off2)
1 = Emergency stop signal (mode off3)
1 = The autoreset function is inhibiting operation
1 = The jogging enable signal is inhibiting operation
Start inhibit status word.
Speed control status word.
This parameter is read-only.
Description
1 = Drive is running at zero speed
1 = Drive is running in forward direction above zero speed limit
(par. 21.06)
1 = Drive is running in reverse direction above zero speed limit
(par. 21.06)
1 = Speed error window control active (see par. 24.41)
1 = Encoder 1 used for speed feedback (see par. 90.41)
1 = Encoder 2 used for speed feedback (see par. 90.41)
1 = A constant speed or frequency has been selected; see par.
06.20.
Speed control status word.
Parameters 97
Def/FbEq16
-
1, bit 1.
1 = 1
-
1 = 1

Advertisement

Table of Contents
loading

Table of Contents