No.
Name/Value
DI5
DI6
DIO1
DIO2
Other [bit]
40.43
Set 1 sleep level
0.0 ... 32767.0
40.44
Set 1 sleep delay
0.0 ... 3600.0 s
40.45
Set 1 sleep boost
time
0.0 ... 3600.0 s
40.46
Set 1 sleep boost
step
0.0 ... 32767.0
40.47
Set 1 wake-up
deviation
-32768.00 ...
32767.00
40.48
Set 1 wake-up
delay
0.00 ... 60.00 s
40.49
Set 1 tracking mode
Not selected
Selected
DI1
DI2
DI3
DI4
Description
Digital input DI5
(10.02 DI delayed
Digital input DI6
(10.02 DI delayed
Digital input/output DIO1
Digital input/output DIO2
Source selection (see
Terms and abbreviations
Defines the start limit for the sleep function when parameter
40.41 Set 1 sleep mode
Sleep start level.
Defines a delay before the sleep function actually becomes
enabled, to prevent nuisance sleeping.
The delay timer starts when the sleep condition selected by
parameter
40.41 Set 1 sleep mode
if the condition becomes false.
Sleep start delay.
Defines a boost time for the sleep boost step. See parameter
40.46 Set 1 sleep boost
Sleep boost time.
When the drive is entering sleep mode, the process setpoint
is increased by this percentage for the time defined by
parameter
40.45 Set 1 sleep boost
If active, sleep boost is aborted when the drive wakes up.
Sleep boost step.
Defines the wake-up level as deviation between process
setpoint and feedback. The unit is selected by parameter
40.12 Set 1 unit
selection.
When the deviation exceeds the value of this parameter, and
remains there for the duration of the wake-up delay
Set 1 wake-up
delay), the drive wakes up.
See also parameter
40.31 Set 1 deviation
Wake-up level (as deviation between process setpoint and
feedback).
Defines a wake-up delay for the sleep function to prevent
nuisance wake-ups. See parameter
deviation.
The delay timer starts when the deviation exceeds the wake-
up level
(40.47 Set 1 wake-up
deviation falls below the wake-up level.
Wake-up delay.
Activates (or selects a source that activates) tracking mode.
In tracking mode, the value selected by parameter
1 tracking ref selection
is substituted for the PID controller
output. See also section
1 = Tracking mode enabled
0.
1.
Digital input DI1
(10.02 DI delayed
Digital input DI2
(10.02 DI delayed
Digital input DI3
(10.02 DI delayed
Digital input DI4
(10.02 DI delayed
status, bit 4).
status, bit 5).
(11.02 DIO delayed
status, bit 0).
(11.02 DIO delayed
status, bit 1).
on page 88).
is set to Internal.
becomes true, and resets
step.
time.
inversion.
40.47 Set 1 wake-up
deviation), and resets if the
Tracking
(page 52).
status, bit 0).
status, bit 1).
status, bit 2).
status, bit 3).
Parameters 235
Def/FbEq16
6
7
10
11
-
0.0
1 = 1
60.0 s
1 = 1 s
0.0 s
1 = 1 s
0.0
1 = 1
0.00
(40.48
1 = 1 unit
0.50 s
1 = 1 s
Not selected
40.50 Set
0
1
2
3
4
5