138 Parameters
No.
Name/Value
15.83
AO1 out at AO1 src
max
16
16 I/O extension
module 3
16.01
Module 3 type
16.02
Module 3 location
16.03
Module 3 status
16.05
DIO status
16.06
DIO delayed status
16.09
DIO1 function
16.10
DIO1 filter gain
16.11
DIO1 output source
16.12
DIO1 ON delay
16.13
DIO1 OFF delay
16.14
DIO2 function
16.15
DIO2 filter gain
16.16
DIO2 output source
16.17
DIO2 ON delay
16.18
DIO2 OFF delay
16.19
DIO3 function
16.21
DIO3 output source
16.22
DIO3 ON delay
16.22
AI force sel
16.23
DIO3 OFF delay
16.24
DIO4 function
16.26
DIO4 output source
16.26
AI1 actual value
16.27
DIO4 ON delay
16.27
AI1 scaled value
Description
(Visible when
15.01 Module 2 type
See parameter
14.83 AO1 out at AO1 src
Configuration of I/O extension module 3.
See also section
Programmable I/O extensions
Note: The contents of the parameter group vary according to
the selected I/O extension module type.
See parameter
14.01 Module 1
See parameter
14.02 Module 1
See parameter
14.03 Module 1
See parameter
14.05 DIO
See parameter
14.06 DIO delayed
See parameter
14.09 DIO1
(Visible when
15.01 Module 2 type
See parameter
14.10 DIO1 filter
See parameter
14.11 DIO1 output
See parameter
14.12 DIO1 ON
See parameter
14.13 DIO1 OFF
See parameter
14.14 DIO2
(Visible when
16.01 Module 3 type
See parameter
14.15 DIO2 filter
See parameter
14.16 DIO2 output
See parameter
14.17 DIO2 ON
See parameter
14.18 DIO2 OFF
(Visible when
16.01 Module 3 type
See parameter
14.19 DIO3
(Visible when
16.01 Module 3 type
See parameter
14.21 DIO3 output
(Visible when
16.01 Module 3 type
See parameter
14.22 DIO3 ON
(Visible when
16.01 Module 3 type
See parameter
14.22 AI force
(Visible when
16.01 Module 3 type
See parameter
14.23 DIO3 OFF
(Visible when
16.01 Module 3 type
See parameter
14.24 DIO4
(Visible when
16.01 Module 3 type
See parameter
14.26 DIO4 output
(Visible when
16.01 Module 3 type
See parameter
14.26 AI1 actual
(Visible when
16.01 Module 3 type
See parameter
14.27 DIO4 ON
(Visible when
16.01 Module 3 type
See parameter
14.27 AI1 scaled
= FIO-11)
max.
(page 29).
type.
location.
status.
status.
status.
function.
= FIO-11)
gain.
source.
delay.
delay.
function.
= FIO-11)
gain.
source.
delay.
delay.
= FIO-01)
function.
= FIO-01)
source.
= FIO-01)
delay.
= FIO-11)
selection.
= FIO-01)
delay.
= FIO-01)
function.
= FIO-01)
source.
= FIO-11)
value.
= FIO-01)
delay.
= FIO-11)
value.
Def/FbEq16
20.000 mA
None
1 (Slot 1)
No option
-
-
Input
7.5 us
Not
energized
0.0 s
0.0 s
Input
7.5 us
Not
energized
0.0 s
0.0 s
Input
Not
energized
0.0 s
00000000h
0.0 s
Input
Not
energized
-
0.0 s
-

Advertisement