51 FBA A settings

51.01
FBA A type
51.02
FBA A Par2
0...65535
...
...
51.26
FBA A Par26
0...65535
51.27
FBA A par refresh
Done
Configure
51.28
FBA A par table ver
Description
Selects the communication time levels.
In general, lower time levels of read/write services reduce
CPU load. The table below shows the time levels of the
read/write services for cyclic high and cyclic low data with
each parameter setting.
Selection
Cyclic high *
Slow
Normal
Fast
Very fast
* Cyclic high data consists of fieldbus Control and Status
words, Ref1, Ref2, Act1 and Act2.
** Cyclic low data consists of the parameter data mapped to
parameter groups
55 FBA B data in
Acyclic data is handled as a background task.
Normal speed.
Fast speed.
Very fast speed.
Slow speed.
Fieldbus adapter A configuration.
Displays the type of the connected fieldbus adapter module.
0 = Module is not found or is not properly connected, or is
disabled by parameter
50.01 FBA A
32 = FCAN; 37 = FDNA; 128, 132 = FENA-11; 135 = FECA;
136 = FEPL; 485 = FSCA.
This parameter is read-only.
Parameters
51.02...51.26
more information, see the documentation of the fieldbus
adapter module. Note that not all of these parameters are
necessarily in use.
Fieldbus adapter configuration parameter.
...
See parameter
51.02 FBA A
Fieldbus adapter configuration parameter.
Validates any changed fieldbus adapter module configuration
settings. After refreshing, the value reverts automatically to
Done.
Note: This parameter cannot be changed while the drive is
running.
Refreshing done.
Refreshing.
Displays the parameter table revision of the fieldbus adapter
module mapping file (stored in the memory of the drive).
In format axyz, where ax = major table revision number; yz =
minor table revision number.
This parameter is read-only.
Parameter table revision of adapter module.
Cyclic low **
10 ms
10 ms
2 ms
10 ms
500 µs
2 ms
250 µs
2 ms
and
56 FBA B data
enable; 1 = FPBA;
are adapter module-specific. For
Par2.
Parameters 261
Def/FbEq16
Fast
out.
0
1
2
3
-
-
1 = 1
...
-
1 = 1
Done
0
1
-
-