ABB ACS880 Firmware Manual page 224

Primary control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

224 Parameters
No.
Name/Value
36.15
PVL speed at peak
-32768.00 ...
32767.00 rpm
36.16
PVL reset date
-
36.17
PVL reset time
-
36.20
AL1 0 to 10%
0.00 ... 100.00%
36.21
AL1 10 to 20%
0.00 ... 100.00%
36.22
AL1 20 to 30%
0.00 ... 100.00%
36.23
AL1 30 to 40%
0.00 ... 100.00%
36.24
AL1 40 to 50%
0.00 ... 100.00%
36.25
AL1 50 to 60%
0.00 ... 100.00%
36.26
AL1 60 to 70%
0.00 ... 100.00%
36.27
AL1 70 to 80%
0.00 ... 100.00%
36.28
AL1 80 to 90%
0.00 ... 100.00%
36.29
AL1 over 90%
0.00 ... 100.00%
36.40
AL2 0 to 10%
0.00 ... 100.00%
36.41
AL2 10 to 20%
0.00 ... 100.00%
36.42
AL2 20 to 30%
0.00 ... 100.00%
Description
Motor speed at the moment the peak value was recorded.
Motor speed at peak.
The date on which the peak value logger was last reset.
Last reset date of the peak value logger.
The time at which the peak value logger was last reset.
Last reset time of the peak value logger.
Percentage of samples recorded by amplitude logger 1 that
fall between 0 and 10%.
Amplitude logger 1 samples between 0 and 10%.
Percentage of samples recorded by amplitude logger 1 that
fall between 10 and 20%.
Amplitude logger 1 samples between 10 and 20%.
Percentage of samples recorded by amplitude logger 1 that
fall between 20 and 30%.
Amplitude logger 1 samples between 20 and 30%.
Percentage of samples recorded by amplitude logger 1 that
fall between 30 and 40%.
Amplitude logger 1 samples between 30 and 40%.
Percentage of samples recorded by amplitude logger 1 that
fall between 40 and 50%.
Amplitude logger 1 samples between 40 and 50%.
Percentage of samples recorded by amplitude logger 1 that
fall between 50 and 60%.
Amplitude logger 1 samples between 50 and 60%.
Percentage of samples recorded by amplitude logger 1 that
fall between 60 and 70%.
Amplitude logger 1 samples between 60 and 70%.
Percentage of samples recorded by amplitude logger 1 that
fall between 70 and 80%.
Amplitude logger 1 samples between 70 and 80%.
Percentage of samples recorded by amplitude logger 1 that
fall between 80 and 90%.
Amplitude logger 1 samples between 80 and 90%.
Percentage of samples recorded by amplitude logger 1 that
exceed 90%.
Amplitude logger 1 samples over 90%.
Percentage of samples recorded by amplitude logger 2 that
fall between 0 and 10%.
Amplitude logger 2 samples between 0 and 10%.
Percentage of samples recorded by amplitude logger 2 that
fall between 10 and 20%.
Amplitude logger 2 samples between 10 and 20%.
Percentage of samples recorded by amplitude logger 2 that
fall between 20 and 30%.
Amplitude logger 2 samples between 20 and 30%.
Def/FbEq16
0.00 rpm
See par.
46.01
-
-
-
-
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%
0.00%
1 = 1%

Advertisement