ABB ACS880 Firmware Manual page 295

Primary control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
Español
Portugues
Nederlands
Français
Dansk
Suomi
Svenska
Russki
Polski
Czech
Türkçe
Chinese (Simplified,
PRC)
96.02
Pass code
0...99999999
96.03
Access levels
active
Bit
Name
0
End user
1
Service
2
Advanced users
3...15
Reserved
000b...111b
96.04
Macro select
Done
Factory
Hand/Auto
PID-CTRL
T-CTRL
Sequence control
FIELDBUS
96.05
Macro active
Factory
Hand/Auto
PID-CTRL
T-CTRL
Description
Spanish.
Portuguese.
Dutch.
French.
Danish.
Finnish.
Swedish.
Russian.
Polish.
Czech.
Turkish.
Simplified Chinese.
Pass codes can be entered into this parameter to activate
further access levels (for example additional parameters).
Pass code.
Shows which access levels have been activated by pass
codes entered into parameter
Active access levels.
Selects the application macro. See chapter
macros
(page 71) for more information.
After a selection is made, the parameter reverts automatically
to Done.
Macro selection complete; normal operation.
Factory macro (see page 72).
Hand/Auto macro (see page 74).
PID control macro (see page 76).
Torque control macro (see page 80).
Sequential control macro (see page 82).
Reserved.
Shows which application macro is currently selected. See
chapter
Application macros
To change the macro, use parameter
Factory macro (see page 72).
Hand/Auto macro (see page 74).
PID control macro (see page 76).
Torque control macro (see page 80).
96.02 Pass
code.
Application
(page 71) for more information.
96.04 Macro
select.
Parameters 295
Def/FbEq16
3082
2070
1043
1036
1030
1035
1053
1049
1045
1029
1055
2052
0
-
001b
-
Done
0
1
2
3
4
5
6
Factory
1
2
3
4

Advertisement

Table of Contents
loading