22 Parameter settings
Index
Name
POUS.21
POUS output
POUS.22
POUS completed
output
I/O parameters
SAFEIO.35 DI X113:3 Diag pulse
on/off
SAFEIO.39 DI X114:3 Diag pulse
on/off
SAFEIO.53 DO X113:7 Diag pulse On
SAFEIO.71 DO X113:7 logic state

FSE module and safety pulse encoder parameters

Set these parameters when you use a safety pulse encoder in the safety application.
Index
Name
200.231 FSE 3X act and
par version
200.232 Number of
encoders
S_ENCGEN.01 Safe pulse
encoder version
S_ENCGEN.11 FSE diagnostic
failure reaction
S_ENCGEN.14 Enc speed cross
comp tolerance
S_ENCGEN.41 Gear numerator
encoder 1
91.11 Module 1 type
91.12 Module 1 location 2
92.01 Encoder 1 type
Example
Description
value
None
Sets the digital output that indicates the activity of the
POUS function. Active from the POUS request until the
function has been acknowledged.
The safety function described in this manual does not use
this digital output.
DO X113:7
Sets the digital output that indicates the completion of the
POUS function. Active after the time defined by parameter
POUS.13
POUS request has been removed and the POUS function
has been acknowledged (automatic acknowledgement is
used, see parameter
For the option +Q950, ABB has configured the POUS
indication signal to this digital output at the factory. Make
sure that this value corresponds to the actual wiring. See
the circuit diagrams of the delivery.
Off
Sets the diagnostic pulse of digital input X113:3 on or off.
Off: The input monitors that it does not receive test pulses.
Off
Sets the diagnostic pulse of digital input X114:3 on or off.
Off: The input monitors that it does not receive test pulses.
Sets the diagnostic pulse of digital output X114:7 on or off.
On: The output monitors that it receives test pulses
Active high
Sets the logic state of digital output X113:7.
Active high: The digital output is on when the indicated
signal is active.
For the option +Q950, ABB has configured the POUS
indication signal to this digital output at the factory.
Example
Description
value
Version 1
Activates the FSE-31 encoder interface and shows the
version of the encoder parameter groups (91 and 92).
Single
Shows the number of safety pulse encoders connected to the
encoder
FSE module.
CH1
Version 1
Activates the safety pulse encoder and shows the version
parameter group S_ENCGEN.
STO
Sets the action taken when there is a problem with the FSE
module.
STO: The FSO module goes into the Fail-safe mode and
activates the drive STO function.
1 rpm
Sets the encoder speed cross comparison tolerance. This
defines how much the axle speed of the motor can change
within 1 ms.
Adjust the default value to meet the motor in use.
1
Sets the rotation direction for the safety pulse encoder.
With this parameter, you can change the rotation direction of
the motor.
Adjust the default value if necessary.
FSE-31
Sets the type of the safety pulse encoder interface module 1.
Sets the slot in which the safety pulse encoder interface
module 1 is located.
HTL1
Activates or deactivates the communication with the safety
pulse encoder interface module 1 and sets the type for the
safety pulse encoder.
has elapsed from the POUS request until the
POUS.02 POUS
acknowledgement).

Advertisement