ABB ACS880 Firmware Manual page 260

Primary control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

260 Parameters
No.
Name/Value
50.41
FBA B act2
transparent source
Not selected
Other
50.42
FBA B debug
enable
Disable
Enable
50.43
FBA B control word
00000000h ...
FFFFFFFFh
50.44
FBA B reference 1
-2147483648 ...
2147483647
50.45
FBA B reference 2
-2147483648 ...
2147483647
50.46
FBA B status word
00000000h ...
FFFFFFFFh
50.47
FBA B actual value
1
-2147483648 ...
2147483647
50.48
FBA B actual value
2
-2147483648 ...
2147483647
Description
When parameter
50.38 FBA B actual 2 type
Transparent, this parameter selects the source of actual value
2 transmitted to the fieldbus network through fieldbus adapter
B.
No source selected.
Source selection (see
Terms and abbreviations
Enables the display of raw (unmodified) data received from
and sent to fieldbus adapter B in parameters 50.43...50.48.
This functionality should only be used for debugging.
Display of raw data from fieldbus adapter B disabled.
Display of raw data from fieldbus adapter B enabled.
Displays the raw (unmodified) control word sent by the
master (PLC) to fieldbus adapter B if debugging is enabled by
parameter
50.42 FBA B debug
This parameter is read-only.
Control word sent by master to fieldbus adapter B.
Displays raw (unmodified) reference REF1 sent by the master
(PLC) to fieldbus adapter B if debugging is enabled by
parameter
50.42 FBA B debug
This parameter is read-only.
Raw REF1 sent by master to fieldbus adapter B.
Displays raw (unmodified) reference REF2 sent by the master
(PLC) to fieldbus adapter B if debugging is enabled by
parameter
50.42 FBA B debug
This parameter is read-only.
Raw REF2 sent by master to fieldbus adapter B.
Displays the raw (unmodified) status word sent by fieldbus
adapter B to the master (PLC) if debugging is enabled by
parameter
50.42 FBA B debug
This parameter is read-only.
Status word sent by fieldbus adapter B to master.
Displays raw (unmodified) actual value ACT1 sent by fieldbus
adapter B to the master (PLC) if debugging is enabled by
parameter
50.42 FBA B debug
This parameter is read-only.
Raw ACT1 sent by fieldbus adapter B to master.
Displays raw (unmodified) actual value ACT2 sent by fieldbus
adapter B to the master (PLC) if debugging is enabled by
parameter
50.42 FBA B debug
This parameter is read-only.
Raw ACT2 sent by fieldbus adapter B to master.
is set to
on page 88).
enable.
enable.
enable.
enable.
enable.
enable.
Def/FbEq16
Not selected
-
-
Disable
0
1
-
-
-
-
-
-
-
-
-
-
-
-