Encoder Module Settings - ABB ACS880 N5700 Series Firmware Manual

Position control program
Table of Contents

Advertisement

No.
Name / Range /
Selection
91
Encoder module
settings
91.1
FEN DI status
b0
DI1 /module 1
b1
DI2 /module 1
b2...3
Reserved
b4
DI1 /module 2
b5
DI2 /module 2
b6...15
Reserved
0000h...FFFFh
91.2
Module 1 status
No option
FEN-01
FEN-11
FEN-21
FEN-31
FSE-31
91.3
Module 2 status
91.4
Module 1
temperature
0.0 ... 1000.0 °
Description
Configuration of encoder interface modules.
Displays the status of the digital inputs of FEN-xx
encoder interface modules.
Note: This parameter is read-only.
DI1 of interface module 1 (see parameters
91.12)
DI2 of interface module 1 (see parameters
91.12)
DI1 of interface module 2 (see parameters
91.14)
DI2 of interface module 2 (see parameters
91.14)
Displays the type of the interface module found in the
location specified by parameter
Note: This parameter is read-only.
No module detected in the specified slot.
A module has been detected but cannot be
communicated with.
The module type is unknown.
An FEN-01 module has been detected and is active.
An FEN-11 module has been detected and is active.
An FEN-21 module has been detected and is active.
An FEN-31 module has been detected and is active.
An FSE-31 module has been detected and is active.
Displays the type of the interface module found in the
location specified by parameter
For the indications, see parameter
Note: This parameter is read-only.
Displays the temperature measured through the sensor
input of interface module 1. The unit (°C or °F) is
selected by parameter
Note: With a PTC sensor, the unit is ohms.
Note: This parameter is read-only.
Temperature measured through interface module 1.
91.11
91.11
91.13
91.13
91.12 Module 1
91.14 Module 2
91.2 Module 1
96.16 Unit
selection.
Parameters 489
Def / Type
FbEq 16b / 32b
- / uint16
and
and
and
and
1 = 1
- / uint16
location.
0
1
2
16
17
18
21
25
- / uint16
location.
status.
- / real32
- / -