ABB ACS880 Firmware Manual page 256

Primary control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

256 Parameters
No.
Name/Value
50.08
FBA A actual 2 type
Auto
Transparent
General
Torque
Speed
Frequency
Position
Velocity
DC voltage
Active power
Reactive power
50.09
FBA A SW
transparent source
Not selected
Other
50.10
FBA A act1
transparent source
Not selected
Other
50.11
FBA A act2
transparent source
Not selected
Other
50.12
FBA A debug
enable
Disable
Enable
Description
Selects the type and scaling of actual value 2 transmitted to
the fieldbus network through fieldbus adapter A. The scaling
of the value is defined by parameters 46.01...46.04,
depending on which actual value type is selected by this
parameter.
Type and scaling is chosen automatically according to the
currently active operation mode as follows:
Operation mode
(see par. 19.01)
Speed control
Torque control
Frequency control
No scaling is applied.
Generic reference without a specific unit.
The scaling is defined by parameter
The scaling is defined by parameter
The scaling is defined by parameter
Reserved.
Reserved.
Reserved.
The scaling is defined by parameter
The scaling is defined by parameter
Selects the source of the fieldbus status word when
parameter
50.06 FBA A SW sel
No source selected.
Source selection (see
Terms and abbreviations
When parameter
50.07 FBA A actual 1 type
Transparent, this parameter selects the source of actual value
1 transmitted to the fieldbus network through fieldbus adapter
A.
No source selected.
Source selection (see
Terms and abbreviations
When parameter
50.08 FBA A actual 2 type
Transparent, this parameter selects the source of actual value
2 transmitted to the fieldbus network through fieldbus adapter
A.
No source selected.
Source selection (see
Terms and abbreviations
Enables the display of raw (unmodified) data received from
and sent to fieldbus adapter A in parameters 50.13...50.18.
This functionality should only be used for debugging.
Display of raw data from fieldbus adapter A disabled.
Display of raw data from fieldbus adapter A enabled.
Actual value 2 type
Torque
Torque
Torque
46.03 Torque
scaling.
46.01 Speed
scaling.
46.02 Frequency
scaling. 5
46.04 Power
scaling.
46.04 Power
scaling.
is set to
Transparent
mode.
on page 88).
is set to
on page 88).
is set to
on page 88).
Def/FbEq16
Auto
0
1
2
3
4
6
7
8
9
10
Not selected
-
-
Not selected
-
-
Not selected
-
-
Disable
0
1