No.
Name/Value
91.24
Temperature meas
sel2
None
PTC
KTY-84
91.25
Temperature
filtering time 2
0...10000 ms
92
92 Encoder 1
configuration
92.01
Encoder 1 type
None
TTL
TTL+
Abs enc
Resolver
HTL
92.02
Encoder 1 source
Module 1
Module 2
92.10
Pulses/rev
0...65535
92.10
Sine/cosine number
0...65535
92.10
Excitation signal
frequency
1...20 kHz
Description
Specifies the type of temperature sensor connected to
interface module 2.
None.
PTC.
KTY84.
Defines a filtering time for the temperature measurement
through interface 2.
Filtering time for temperature measurement.
Settings for encoder 1.
Notes:
• The contents of the parameter group vary according to the
selected encoder type.
• It is recommended that encoder connection 1 (this group)
is used whenever possible since the data received through
that interface is fresher than the data received through
connection 2 (group
93 Encoder 2
Activates the communication with optional encoder/resolver
interface module 1.
Inactive.
Communication active. Module type: FEN-01 TTL Encoder
Interface. Input: TTL encoder input (X31).
Communication active. Module type: FEN-01 TTL Encoder
interface. Input: TTL encoder input with commutation support
(X32).
Communication active. Module type: FEN-11 Absolute
Encoder Interface. Input: Absolute encoder input (X42).
Communication active. Module type: FEN-21 Resolver
Interface. Input: Resolver input (X52).
Communication active. Module type: FEN-31 HTL Encoder
Interface. Input: HTL encoder input (X82).
Selects the interface module that the encoder is connected
to. (The physical locations and types of encoder interface
modules are defined in parameter group
settings.)
Interface module 1.
Interface module 2.
(Visible when
92.01 Encoder 1 type
Defines the pulse number per revolution.
Number of pulses.
(Visible when
92.01 Encoder 1 type
Defines the number of sine/cosine wave cycles within one
revolution.
Note: This parameter need not be set when an EnDat or SSI
encoder is used in continuous mode. See parameter
Serial link
mode.
Number of sine/cosine wave cycles within one revolution.
(Visible when
92.01 Encoder 1 type
Defines the frequency of the excitation signal.
Excitation signal frequency.
Parameters 285
configuration).
91 Encoder module
= TTL,
TTL+
or HTL)
=
Abs
enc)
92.30
= Resolver)
Def/FbEq16
None
0
1
2
1500 ms
-
None
0
1
2
3
4
5
Module 1
1
2
2048
-
0
-
1 kHz
1 = 1 kHz