ABB ACS880 Firmware Manual page 99

Primary control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
06.50
User status word 1
Bit
Name
0
User status bit 0
1
User status bit 1
...
...
15
User status bit 15
0000h...FFFFh
06.60
User status word 1
bit 0 sel
False
True
Other [bit]
06.61
User status word 1
bit 1 sel
False
True
Out of window
Other [bit]
06.62
User status word 1
bit 2 sel
False
True
Emergency stop
failed
Other [bit]
06.63
User status word 1
bit 3 sel
False
True
Magnetized
Other [bit]
06.64
User status word 1
bit 4 sel
False
True
Run disable
Other [bit]
06.65
User status word 1
bit 5 sel
False
True
Description
User-defined status word. This word shows the status of the
binary sources selected by parameters 06.60...06.75.
This parameter is read-only.
Description
Status of source selected by parameter
Status of source selected by parameter
...
Status of source selected by parameter
User-defined status word.
Selects a binary source whose status is shown as bit 0 of
06.50 User status word
0.
1.
Source selection (see
Terms and abbreviations
Selects a binary source whose status is shown as bit 1 of
06.50 User status word
0.
1.
Bit 3 of
06.19 Speed control status word
Source selection (see
Terms and abbreviations
Selects a binary source whose status is shown as bit 2 of
06.50 User status word
0.
1.
Bit 8 of
06.17 Drive status word 2
Source selection (see
Terms and abbreviations
Selects a binary source whose status is shown as bit 3 of
06.50 User status word
0.
1.
Bit 1 of
06.17 Drive status word 2
Source selection (see
Terms and abbreviations
Selects a binary source whose status is shown as bit 4 of
06.50 User status word
0.
1.
Bit 5 of
06.18 Start inhibit status word
Source selection (see
Terms and abbreviations
Selects a binary source whose status is shown as bit 5 of
06.50 User status word
0.
1.
1.
1.
(see page 97).
1.
(see page 96).
1.
(see page 96).
1.
(see page 97).
1.
Parameters 99
Def/FbEq16
-
06.60
06.61
06.75
1 = 1
False
0
1
on page 88).
-
Out of
window
0
1
2
on page 88).
-
Emergency
stop failed
0
1
2
on page 88).
-
Magnetized
0
1
2
on page 88).
-
Run disable
0
1
2
on page 88).
-
False
0
1

Advertisement

Table of Contents
loading

Table of Contents