No.
Name/Value
62.32
Follower node 3
data 2 value
0...65535
62.33
Follower node 3
data 3 value
0...65535
62.34
Follower node 4
data 1 value
0...65535
62.35
Follower node 4
data 2 value
0...65535
62.36
Follower node 4
data 3 value
0...65535
62.51
Data set 10 data 1
selection
None
CW 16bit
Ref1 16bit
Ref2 16bit
Other
62.52
Data set 10 data 2
selection
Description
Displays, in integer format, the data received from the second
follower (ie. follower with node address 3) as word 2.
Parameter
62.08 Follower node 3 data 2 sel
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
Data received as word 2 from follower with node address 3.
Displays, in integer format, the data received from the second
follower (ie. follower with node address 3) as word 3.
Parameter
62.09 Follower node 3 data 3 sel
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
Data received as word 3 from follower with node address 3.
Displays, in integer format, the data received from the third
follower (ie. follower with node address 4) as word 1.
Parameter
62.10 Follower node 4 data 1 sel
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
Data received as word 1 from follower with node address 4.
Displays, in integer format, the data received from the third
follower (ie. follower with node address 4) as word 2.
Parameter
62.11 Follower node 4 data 2 sel
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
Data received as word 2 from follower with node address 4.
Displays, in integer format, the data received from the third
follower (ie. follower with node address 4) as word 3.
Parameter
62.12 Follower node 4 data 3 sel
select a target for the received data. This parameter can also
be used as a signal source by other parameters.
Data received as word 3 from follower with node address 4.
Parameters
62.51...62.74
received in data sets 10, 12, 14, 16, 18, 20, 22 and 24 from
the external controller.
Parameters
62.101...62.124
the external controller in integer format, and can be used as
sources by other parameters.
For example, this parameter selects a target for word 1 of
data set 10. Parameter
displays the received data in integer format, and can also be
used as a source by other parameters.
None.
Control Word (16 bits)
Reference REF1 (16 bits)
Reference REF2 (16 bits)
Source selection (see
Terms and abbreviations
Defines a target for the data received as word 2 of data set
10.
See also parameter
62.102 Data set 10 data 2
For the selections, see parameter
selection.
can be used to
can be used to
can be used to
can be used to
can be used to
define a target for the data
display the data received from
62.101 Data set 10 data 1 value
value.
62.51 Data set 10 data 1
Parameters 277
Def/FbEq16
0
0
0
0
0
None
0
1
2
3
on page 88).
-
None