3EM13853AF
Issue 01, September 2007
TAP-145

MEM-ACCESS-DF Alarm

PURPOSE
This procedure provides instructions to clear a MEM-ACCESS-DF alarm on an IOC module.
GENERAL
MEM-ACCESS-DF indicates system clock alarm detected on an IOC module.
STEP
PROCEDURE
1
DANGER: Possibility of personal injury. Modules can be installed or removed with
rack power on. Hazardous electrical potentials are present; use extreme care when
installing or removing modules with power on.
WARNING: Possibility of equipment damage. Modules contain electrostatic-
2
sensitive devices (ESDs). These devices can be damaged by static discharge.
Refer to
Enter
3
Observe output. Note module with MEM-ACCESS-DF alarm.
4
Enter
5
where: AID=Equipment access identifier of card with MEM-ACCESS-DF alarm
Did command return COMPLD or DENY?
6
Enter
7
where: AID=Equipment access identifier of card with MEM-ACCESS-DF alarm
Did command return COMPLD or DENY?
8
Enter
9
where: AID=Equipment access identifier of card with MEM-ACCESS-DF alarm
MEM-ACCESS-DF Alarm
Introduction
for special handling instructions.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
RMV-EQPT::AID;
If COMPLD, go to step 7.
If DENY, go to step 16.
INIT-SYS::AID:::;
If COMPLD, go to step 9.
If DENY, go to step 16.
.
RST-EQPT::AID;
to retrieve all alarms and conditions.
TAP-145
4-111