Alcatel-Lucent 1677 SONET Maintenance And Trouble Clearing page 220

Hide thumbs Also See for 1677 SONET:
Table of Contents

Advertisement

DLP-128
Did output return COMPLD or DENY?
31
Enter
32
where: AID=Access Identifier of CCC to be replaced.
Did output return COMPLD or DENY?
33
Enter
34
Observe output.
35
Enter
36
Observe output.
37
Identify the TC associated with CCC to be replaced. Refer to table-128-A.
38
What is PST,SST of TC associated with the CCC to be replaced?
39
Enter
40
proceeding.
where:
x=A or B (slot number of TC associated with CCC to be replaced)
Enter
41
Observe output.
42
Enter
43
Observe output.
44
What is PST,SST of TC to be replaced?
45
5-30
If COMPLD, go to step 32.
If DENY, go to step 109.
for CCC to be replaced.
RMV-EQPT::AID;
If COMPLD, go to step 34.
If DENY, go to step 109.
RTRV-EQPT::TC-11-A;
RTRV-EQPT::TC-11-B;
If IS,WRK, go to step 40.
If IS,STBYH, go to step 46.
SW-DX-EQPT::TC-11-x;
RTRV-EQPT::TC-11-A;
RTRV-EQPT::TC-11-B;
If IS,WRK, go to step 109.
If IS,STBYH, go to step 46.
Wait five minutes after Standby TC restores before
Issue 01, September 2007
Replace Common Control Card (CCC)
3EM13853AF