Inhmsg-Pm Alarm - Alcatel-Lucent 1677 SONET Maintenance And Trouble Clearing

Hide thumbs Also See for 1677 SONET:
Table of Contents

Advertisement

3EM13853AF
Issue 01, September 2007
TAP-129

INHMSG-PM Alarm

PURPOSE
This procedure provides instructions to clear an INHMSG-PM alarm against the CHASSIS and clear
an INHMSG-PM alarm against a specific facility.
GENERAL
INHMSG-PM indicates PM reports are inhibited for all entities. This condition was caused by
execution of the INH-PMREPT-COM command.
The ALW-PMREPT-COM command used in this procedure does not affect any inhibitions set for
individual ports through the INH-PMREPT-rr command.
For information on TL1 command syntax, refer to the 1677 SONET Link Commands and Messages
manual (PN 3EM13852AF).
STEP
PROCEDURE
Are performance monitoring reports to be allowed for all entities?
1
Enter
2
Did output return COMPLD or DENY?
3
Enter
4
Did INHMSG-PM alarm clear for CHASSIS?
5
Are performance monitoring reports to be allowed for a specific facility?
6
Enter
7
EC1/GIGE/OC3/OC12/OC48/OC192/OFA/STS1/STS3C/STS12C/STS48C/T1/T3/VT1::AID:;
INHMSG-PM Alarm
If yes, go to step 2.
If no, go to step 6.
ALW-PMREPT-COM;
If COMPLD, go to step 4.
If DENY, go to step 11.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 12.
If no, go to step 11.
If yes, go to step 7.
If no, go to step 12.
ALW-PMREPT-
to retrieve all alarms and conditions.
TAP-129