TAP-100
L2LCONFAIL or L2SCONFAIL
L2LCONFAIL indicates Layer 2 Line DCC connection failure. L2SCONFAIL
107
indicates Layer 2 Section DCC connection failure.
Go to step 160.
LCPLCONFAIL or LCPSCONFAIL
LCPLCONFAIL indicates LCP Line DCC connection failure. LCPSCONFAIL
108
indicates LCP Section DCC connection failure. These alarms are raised after
MAXCONFIG count is exhausted.
Go to step 160.
LCPLDF or LCPSDF
LCPLDF indicates Line DCC failure. LCPSDF indicates LCP Section DCC failure.
109
These alarms are raised after MAXTERM count is exhausted, ECHOREPCOUNT is
exhausted, or reception of code reject.
LOCC
LOCC indicates Loss of Client Character Synchronization on a GIGE facility.
110
Go to step 160.
LOCKOUTOFPR
LOCKOUTOFPR indicates lockout of a protection OC3, OC12, OC48, or OC192
111
facility. The protect facility is locked out of use by any associated working facility. This
condition is initiated by OPR-PROTNSW-OCn command.
Is lockout of protection to be released?
Enter
112
where:
OCn=Facility type (OC3, OC12, OC48, OC192)
AID=Facility Access Identifier
Did output return COMPLD or DENY?
113
4-16
If yes, go to step 112.
If no, go to step 161.
RLS-PROTNSW-OCn::AID;
If COMPLD, go to step 161.
If DENY, go to step 160.