Alcatel-Lucent 1677 SONET Maintenance And Trouble Clearing page 78

Hide thumbs Also See for 1677 SONET:
Table of Contents

Advertisement

TAP-100
Enter
68
where:
OCn=Optical facility (OC-48 or OC-192)
AID=West OC-n facility access identifier
Enter
69
where:
OCn=Optical facility type (OC-48 or OC-192)
PROTECTED_ID=OC-48/OC-192 access identifier
NODEID=New value of node identifier (0-15)
Enter
70
where:
OCn=Optical facility (OC-48 or OC-192)
AID=West OC-n facility access identifier
Enter
71
where:
OCn=Optical facility (OC-48 or OC-192)
AID=East OC-n facility access identifier
Enter
72
where:
OCn=Optical facility type (OC-48 or OC-192)
AID=OC-48/OC192 access identifier
Enter
73
Did BLSRAD-DUPNODE condition clear?
74
BLSRAD-OSI-ERR
BLSRAD-OSI-ERR indicates node is unable to communicate with its neighbor. Go to
75
step 160.
4-10
OPR-PROTNSW-OCn::AID:::LOP-S;
ED-FFP-OCn::PROTECTED_ID::::,NODEID=
RLS-PROTNSW-OCn::AID;
RLS-PROTNSW-OCn::AID;
RTRV-FFP-OCn::[AID];
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 161.
If no, go to step 160.
;
to verify new node ID value.
and observe output.