Alcatel-Lucent 1677 SONET Maintenance And Trouble Clearing page 81

Hide thumbs Also See for 1677 SONET:
Table of Contents

Advertisement

3EM13853AF
Issue 01, September 2007
CGAAIS
CGAAIS indicates system is detecting incoming Alarm Indication Signal - Carrier
90
Group Alarm.
Problem is outside system. Go to step 160.
CGARED
CGARED indicates system is detecting incoming Red - Carrier Group Alarm.
91
Problem is outside system. Go to step 160.
CGAYEL
CGAYEL indicates the adjacent NE is detecting a problem coming from the
92
1677 SONET Link.
Enter
where: AID=Access Identifier of either DS0G module in the pair
Enter
93
Did CGAYEL alarm clear?
94
EOC or EOCL
EOC indicates Embedded Operations Channel failure on section DCC. EOCL
95
indicates Embedded Operations Channel failure on line DCC. Go to step 160.
Facility Alarm or Event
to copy switch the supporting DS0G modules.
SW-DX-EQPT::AID;
and observe output.
RTRV-COND-ALL;
If yes, go to step 161.
If no, go to step 160.
TAP-100
4-13