DLP-129
Align replacement panel with mounting hole on adapter plate, then use a #2 Phillips
22
screwdriver to tighten mounting thumbscrews.
WARNING: Possibility of equipment damage. To prevent thumbscrew damage,
23
never tighten a thumbscrew with a power screwdriver or more than .09 m-kg
(8 in.-lbs).
Pull adapter plate away from equipment rack. Use #2 Phillips screwdriver to attach
24
cable-tie brackets to replacement connector panel.
Reattach adapter plate to equipment rack. Use #2 Phillips screwdriver to tighten
25
screws.
Reinstall cable in rear connector of panel. Use #2 Phillips screwdriver to tighten
26
screws.
Reconnect cables to transmit and receive ports on front of connector panel.
27
Secure cables to cable-tie brackets.
28
29
STOP. This procedure is complete.
5-42
3EM13853AF
Issue 01, September 2007
Replace DS3 Connector Panel