3EM13853AF
Issue 01, September 2007
TAP-120

USTHRESHOLD Alarm

PURPOSE
This procedure provides instructions to clear a USTHRESHOLD alarm against a TMUX or VSC.
GENERAL
USTHRESHOLD indicates resource module usage has reached 80%.
For information on TL1 command syntax, refer to the 1677 SONET Link Commands and Messages
manual (PN 3EM13852AF).
STEP
PROCEDURE
Enter
1
Observe output.
2
Is module usage percentage to be reduced?
3
Module resource usage can be reduced by deleting cross-connections or by adding
4
another TMUX or VSC module, if possible. Refer to the Operation and Administration
manual (PN 3EM13851AF).
Go to step 7.
5
Contact next level of technical support for assistance.
6
7
STOP. This procedure is complete.
USTHRESHOLD Alarm
RTRV-USAGE-EQPT;
If yes, go to step 4.
If no, go to step 7.
TAP-120
4-61