3EM13853AF
Issue 01, September 2007
Enter
20
ACT-DISK::AID::::ACTION=UNMOUNT;
replaced.
where: AID=Access Identifier of disk on CCC to be replaced (DISK-{A9, A10}).
When disks in CCC that is not being replaced become active, disks on CCC that must
be replaced become inactive.
Enter
21
ACT-DISK::AID::::ACTION=UNMOUNT;
replaced.
where: AID=Access Identifier of disk on CCC to be replaced (DISK-{B9, B10}).
Enter
22
where: AID=Access Identifier of disk on CCC to be replaced (DISK-{A9, A10}).
Enter
23
where: AID=Access Identifier of disk on CCC to be replaced (DISK-{B9, B10}).
Observe output. Note value of TOTAL, FREE, and PST. If disk is unmounted, those
24
parameters should have the following values:
PST=OOS-MA
TOTAL=0
FREE=0
Did output indicate disks are unmounted?
25
Enter
26
Enter
27
Observe output.
28
What is PST,SST of CCC to be replaced?
29
Enter
30
where: AID=Access Identifier of either CCC
Replace Common Control Card (CCC)
to verify the "A" disk on CCC to be replaced are unmounted.
RTRV-DISK::AID;
to verify the "B" disk on CCC to be replaced are unmounted.
RTRV-DISK::AID;
If yes, go to step 26.
If no, go to step 109.
RTRV-EQPT::CCC-9;
RTRV-EQPT::CCC-10;
If IS,WRK, go to step 30.
If IS,STBYH, go to step 32.
to switch CCC to replace to standby.
SW-DX-EQPT::AID;
to unmount the "A" disk on CCC to be
to unmount the "B" disk on CCC to be
DLP-128