Alcatel-Lucent 1677 SONET Maintenance And Trouble Clearing page 164

Hide thumbs Also See for 1677 SONET:
Table of Contents

Advertisement

TAP-137
Enter
9
where: AID=Equipment access identifier of card with FACTERM alarm
Did command return COMPLD or DENY?
10
Enter
11
where: AID=Equipment access identifier of card with FACTERM alarm
Did output return COMPLD or DENY?
12
Enter
13
Observe output. Did FACTERM alarm clear?
14
Replace card with FACTERM alarm. Refer to
15
procedures.
Enter
16
Did FACTERM alarm clear?
17
Contact next level of technical support for assistance.
18
19
STOP. This procedure is complete.
4-96
INIT-SYS::AID:::0;
If COMPLD, go to step 13.
If DENY, go to step 15.
.
RST-EQPT::AID;
If COMPLD, go to step 13.
If DENY, go to step 18.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 19.
If no, go to step 15.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 19.
If no, go to step 18.
Issue 01, September 2007
to retrieve all alarms and conditions.
IXL-103
for card replacement
3EM13853AF
FACTERM Alarm