TAP-100
FEAC Alarms
The following alarms indicate failure at remote terminal:
96
Go to step 160.
FEPRLF
FEPRLF indicates far end protection failure on one of the following ports: OC-3,
97
OC-12, OC-48, or OC-192. This failure is applicable to 1+1 bidirectional FFP
provisioned facilities. It applies to the protection OC-n facility.
Check far-end OC-3, OC-12, OC-48, and OC-192 provisioning. Correct provisioning if
necessary. Refer to 1677 SONET Link Operation and Administration manual
(PN 3EM13851AF). Then go to step 161.
FRCDWKSWBK, FRCDWKSWPR, or FRCDWKSWPR-RING
FRCDWKSWBK indicates forced switch of service from protect to working.
98
FRCDWKSWPR indicates forced switch of service from working to protect. This
condition is a result of the OPR-PROTNSW-OCn (n=3, 12, 48, or 192) command.
Is forced switch to be released?
Enter
99
where:
OCn=Facility type (OC3, OC12, OC48, OC192)
AID=Facility Access Identifier
4-14
FEACAIS
FEACDS1EFAILNSA or FEACDS1EFAILSA
FEACDS1LOS
FEACDS1MLOS
FEACEFAILCOM
FEACEFAILNSA or FEACEFAILSA
FEACISD
FEACLOF
FEACLOS
If yes, go to step 99.
If no, go to step 161.
RLS-PROTNSW-OCn::AID;
3EM13853AF
Issue 01, September 2007
Facility Alarm or Event