Impropins Alarm - Alcatel-Lucent 1677 SONET Maintenance And Trouble Clearing

Hide thumbs Also See for 1677 SONET:
Table of Contents

Advertisement

3EM13853AF
Issue 01, September 2007
TAP-143

IMPROPINS Alarm

PURPOSE
This procedure provides instructions to clear a IMPROPINS alarm against a TC card.
GENERAL
IMPROPINS indicates timing card is not compatible with existing one.
For information on TL1 command syntax, refer to the 1677 SONET Link Commands and Messages
manual (PN 3EM13852AF).
STEP
PROCEDURE
1
DANGER: Possibility of personal injury. Modules can be installed or removed with
rack power on. Hazardous electrical potentials are present; use extreme care when
installing or removing modules with power on.
WARNING: Possibility of equipment damage. Modules contain electrostatic-
2
sensitive devices (ESDs). These devices can be damaged by static discharge.
Refer to
Enter
3
Observe output. Note module with IMPROPINS alarm.
4
Replace card with IMPROPINS alarm. Ensure replacement card is the latest revision.
5
Refer to appropriate TC module UDS in the 1677 SONET Link Product Information
manual for module revision information. Refer to
procedures.
Enter
6
Did IMPROPINS clear?
7
Contact next level of technical support for assistance.
8
9
STOP. This procedure is complete.
IMPROPINS Alarm
Introduction
for special handling instructions.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 9.
If no, go to step 8.
to retrieve all alarms and conditions.
IXL-103
for card replacement
TAP-143
4-107