RTL-101
MONLEV=Discrimination level of the requested monitored parameter, given in the
form n-
reports only if the value of the parameter is 1 or higher;
1-UP
value is 2 or lower.
TMPER=Accumulation period for the counter: either
MONDAT=Starting date of the data to retrieve, or is omitted for the current date.
MONTM=Starting time of the data to retrieve, or is omitted for the current time.
Examine output.
3
Go to step 1.
4
Initialize PM Registers
Enter
5
where:
x=Facility Type (EC1, GIGE, OC3, OC12, OC48, OC192, OFA, STS1, STS3C, STS12C,
STS48C, T1, T3, VT1).
AID=Access Identifier of the facility.
MONTYPE=Threshold (monitored parameter) name, or is omitted for all thresholds
for the facility type.
MONVAL=New value for the register, or is omitted to use the default value 0.
LOCN=Location associated with command (NEND or FEND)
TMPER=Accumulation period for the counter: either
Go to step 1.
6
Retrieve Threshold Values
Enter
7
or
RTRV-TH-x::[AID]:::[MONTYPE],,[TMPER];
where:
rr in the command name is the type of facility (EC1, GIGE, OC3, OC12, OC48, OC192,
OFA, STS1, STS3C, STS12C, STS48C, T1, T3, VT1).
AID=Access identifier of the facility, or is omitted for all facilities of that type.
MONTYPE=Threshold (monitored parameter) name, or is omitted for all thresholds.
TMPER=Accumulation period for the counter: either
3-4
or n-
, where n is an integer in the range 0-255 (optional). For example,
UP
DN
INIT-REG-x::AID:::[MONTYPE],[MONVAL],[LOCN],,[TMPER
RTRV-TH-ALL:::::[MONTYPE],,[TMPER];
3EM13853AF
Issue 01, September 2007
reports only if the
2-DN
(default) or
15-MIN
1-DAY
]
,,;
(default) or
15-MIN
1-DAY
(default) or
15-MIN
1-DAY
Performance Monitoring
.
.
.