TAP-117
Enter
8
where:
AID=Equipment Access Identifier of module
Did output return COMPLD or DENY?
9
Enter
10
where:
AID=Equipment Access Identifier of working module
Did output return COMPLD or DENY?
11
Enter
12
Observe output. Did FRCDWKSWPR or MANWKSWPR alarm clear?
13
Contact next level of technical support for assistance.
14
15
STOP. This procedure is complete.
4-56
RST-EQPT::AID;
If COMPLD, go to step 10.
If DENY, go to step 14.
SW-TOWKG-EQPT::AID;
If COMPLD, go to step 12.
If DENY, go to step 14.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 15.
If no, go to step 14.
Issue 01, September 2007
;
FRCDWKSWPR or MANWKSWPR Alarm