Idromreaderr Alarm - Alcatel-Lucent 1677 SONET Maintenance And Trouble Clearing

Hide thumbs Also See for 1677 SONET:
Table of Contents

Advertisement

3EM13853AF
Issue 01, September 2007
TAP-144

IDROMREADERR Alarm

PURPOSE
This procedure provides instructions to clear a IDROMREADERR alarm on a CCC, SSC, TC, DISK,
IOC, or MOS module.
GENERAL
IDROMREADERR indicates physical ID ROM could not be read.
STEP
PROCEDURE
Enter
1
Observe output. Note AID of module in alarm.
2
Replace module reporting IDROMREADERR alarm. Refer to IXL
3
module replacement procedure.
Did IDROMREADERR alarm clear?
4
Contact next level of technical support for assistance.
5
6
STOP. This procedure is complete.
IDROMREADERR Alarm
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step
If no, go to step
to retrieve all alarms and conditions.
6
5
TAP-144
103
for the correct
4-109