Clean Fiber-Optic Connectors - Alcatel-Lucent 1677 SONET Maintenance And Trouble Clearing

Hide thumbs Also See for 1677 SONET:
Table of Contents

Advertisement

3EM13853AF
Issue 01, September 2007
Detailed Level Procedures (DLPs)
DLP-100

Clean Fiber-Optic Connectors

PURPOSE
This procedure provides the recommended instructions to clean fiber-optic connectors found in
Alcatel-Lucent equipment.
PREREQUISITE
Anyone who performs this procedure must be familiar with cleaning fiber-optic connectors and with
the specific system on which the procedure is to be performed.
This procedure must not be performed on traffic-carrying equipment. If a system is in service, traffic
must be removed from equipment to be cleaned.
RECOMMENDED TOOLS
The following tools must be available for this procedure:
Optical power meter with standard accessories
Optical power meter adapter
Inspection microscope, 200X to 400X—Aerotech World Trade Ltd. AWT200
or AWT300
Inspection microscope tip
Anti-static lint-free swab—Texwipe PN TX757E
CLETOP
fiber-optic connectors except MPX and bulkhead type
CLETOP
box of 200
CLETOP
box of 200
1. CLETOP is a registered trademark of NTT International.
Clean Fiber-Optic Connectors
Spider, MPX-to-SC, 2-meter, single-mode, 8-fiber—AMP 492328-2
Spider, MPX-to-SC, 2-meter, multimode, 8-fiber—AMP 97-A169-62-2
MPX tip—Aerotech World Trade Ltd. AWT-MPX
MPX backplane tip—Aerotech World Trade Ltd. AWT-MPXAPC
®1
fiber-optic cleaner, Aerotech World Trade Ltd. PN 14100500 for all
®
2.5mm Stick-Type cleaner- Aerotech World Trade Ltd. PN 14100400,
®
1.25mm Stick-Type cleaner - Aerotech World Trade Ltd. PN 14100401