Alcatel-Lucent 1677 SONET Maintenance And Trouble Clearing page 118

Hide thumbs Also See for 1677 SONET:
Table of Contents

Advertisement

TAP-113
After 10 seconds, insert same module into slot.
10
Enter
11
Did output return COMPLD or DENY?
12
Enter
13
Did CONTR alarm clear?
14
Replace module with CONTR alarm. Refer to one of the following procedures:
15
Enter
16
Did CONTR alarm clear?
17
Contact next level of technical support for assistance.
18
19
STOP. This procedure is complete.
4-50
RST-EQPT::N-R-Sh-S;
If COMPLD, go to step 13.
If DENY, go to step 15.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 19.
If no, go to step 15.
CCC:
DLP-128
SSC:
DLP-136
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 19.
If no, go to step 18.
for module in alarm.
3EM13853AF
Issue 01, September 2007
CONTR Alarm