Alcatel-Lucent 1677 SONET Maintenance And Trouble Clearing page 75

Hide thumbs Also See for 1677 SONET:
Table of Contents

Advertisement

3EM13853AF
Issue 01, September 2007
Enter
38
where:
OCn=Optical facility type (OC3, OC12, OC48, or OC192)
AID=Facility Access Identifier
Observe output and note primary and secondary states.
39
Does the alarmed OC-n facility have secondary state of WRK or STBYH?
40
Enter
41
where:
OCn=Optical facility type (OC3, OC12, OC48, or OC192)
AID=Facility Access Identifier
Enter
42
Observe output. Note AID in alarm.
43
Enter
44
where:
OCn=Optical facility type (OC3, OC12, OC48, or OC192)
AID=Facility Access Identifier
Observe output and note primary and secondary states.
45
Does the alarmed OC-n facility have secondary state of WRK or STBYH?
46
Enter
47
OPR-PROTNSW-OCn::AID:::MAN;
far-end.
where:
OCn=Optical facility type (OC3, OC12, OC48, or OC192)
AID=Facility Access Identifier
48
CAUTION: Possibility of service interruption. Follow
avoid interrupting service.
Replace OC-n card. Refer to DLP-135. Then go to step 50.
49
Facility Alarm or Event
for facility in alarm.
RTRV-OCn::AID;
If WRK, go to step 41.
If STBYH, go to step 42.
OPR-PROTNSW-OCn::AID:::MAN;
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
for facility in alarm (far-end).
RTRV-OCn::AID;
If WRK, go to step 47.
If STBYH, go to step 48.
to switch service away from alarmed facility.
at far-end NE.
to switch service away from alarmed facility at
DLP-135
TAP-100
when replacing a card to
4-7

Advertisement

Table of Contents
loading