Alcatel-Lucent 1677 SONET Maintenance And Trouble Clearing page 236

Hide thumbs Also See for 1677 SONET:
Table of Contents

Advertisement

DLP-130
Is state of DS3 card IS, STBYH?
24
Replacement DS3 card should be in standby state within 3 minutes. Repeat step 23.
25
If card is not in "IS, STBYH" state after 5 minutes, go to step 31.
Is DS3 card just replaced a protect module (located in slots IOC-1-A, IOC-1-B,
26
IOC-17-A, or IOC-17-B)?
Enter
27
where:
AID=Equipment Access Identifier of the DS3 card just replaced.
Go to step 32.
28
Enter
29
where:
AID=Equipment Access Identifier of the DS3 card just replaced.
Go to step 32.
30
Contact next level of technical support for assistance.
31
32
STOP. This procedure is complete.
5-46
If yes, go to step 26.
If no, go to step 25.
If yes, go to step 27.
If no, go to step 29.
ALW-SWTOPROTN-EQPT::AID;
ALW-SWTOWKG-EQPT::AID;
to allow switching to protection.
to allow switching to working.
Replace DS3 Card with a DS3 Card
3EM13853AF
Issue 01, September 2007

Advertisement

Table of Contents
loading