3EM13853AF
Issue 01, September 2007
TAP-148

RARFAIL (SSC)

PURPOSE
This procedure provides instructions to clear Rearrangement Failure (RARFAIL) alarm/condition.
GENERAL
Rearrangement failure is an indication connections can not be routed through the SSC module.
STEP
PROCEDURE
Enter
1
conditions.
Observe output. Note module with RARFAIL alarm.
2
Enter
3
Enter
4
Verify the SST of both SSC modules. Is one SSC module WRK and the other SSC
5
module STBYH?
Enter
6
where: AID=Access Identifier of either SSC
Enter
7
Did RARFAIL alarm clear?
8
Contact next level of technical support for assistance.
9
10
STOP. This procedure is complete.
RARFAIL (SSC)
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
to retrieve state of SSC in slot seven.
RTRV-EQPT::SWC-7;
to retrieve state of SSC in slot eight.
RTRV-EQPT::SWC-8;
If yes, go to step 6.
If no, go to step 9.
to switch SSC in RARFAIL alarm.
SW-DX-EQPT::AID;
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 10.
If no, go to step 9.
to retrieve equipment alarms and
to retrieve equipment alarms.
TAP-148