3EM13853AF
Issue 01, September 2007
TAP-127

FWMISM Alarm

PURPOSE
This procedure provides instruction to clear a FWMISM alarm on a CCC, SSC, and TMUX module.
GENERAL
FWMISM indicates the FPGA revision of a CCC, SSC, or TMUX module does not match the software
expected version.
For information on TL1 command syntax, refer to the 1677 SONET Link Commands and Messages
manual (PN 3EM13852AF).
STEP
PROCEDURE
1
DANGER: Possibility of personal injury. Modules can be installed or removed with
rack power on. Hazardous electrical potentials are present; use extreme care when
installing or removing modules with power on.
WARNING: Possibility of equipment damage. Modules contain electrostatic-
2
sensitive devices (ESDs). These devices can be damaged by static discharge.
Refer to
Enter
3
Observe output. Note module with FWMISM alarm.
4
Is the module with FWMISM alarm CCC, SSC, or TMUX?
5
Enter
6
where: AID=Equipment Access Identifier of CCC or SSC card.
Is SWVER=current running software?
7
Enter
8
where: AID=Equipment Access Identifier of CCC or SSC card in alarm.
FWMISM Alarm
Introduction
for special handling instructions.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If CCC or SSC, go to step 6.
If TMUX, go to step 16.
to check SWVER of CCC or SSC in FWMISM alarm.
RTRV-EQPT::AID;
If yes, go to step 16.
If no, go to step 8.
to remove CCC or SSC card in FWMISM alarm.
RMV-EQPT::AID;
TAP-127
4-77