Alcatel-Lucent 1677 SONET Maintenance And Trouble Clearing page 263

Hide thumbs Also See for 1677 SONET:
Table of Contents

Advertisement

3EM13853AF
Issue 01, September 2007
23
CAUTION: Possibility of service interruption. Any delay or restart of the SSC (INIT-SYS,
autonomous restart, etc.) during its synchronization period may cause service interruption.
Enter
24
where: AID=Access Identifier of SSC just replaced.
Did output return COMPLD or DENY?
25
Enter
26
Observe output.
27
Is a CONTR alarm set against SSC?
28
Enter
29
Enter
30
Observe output. Note states of modules and firmware version.
31
Is state of both SSC modules IS?
32
Is firmware version (FWVER) the same for both modules?
33
Enter
34
Enter
35
Observe output. Note firmware version.
36
Is firmware version (FWVER) the same for both modules?
37
Replace STS Switch Card (SSC)
for module just replaced.
RST-EQPT::AID;
If COMPLD, go to step 26.
If DENY, go to step 42.
RTRV-COND-EQPT;
If yes, go to step 42.
If no, go to step 29.
to retrieve state of SSC.
RTRV-EQPT::SWC-7;
to retrieve state of other SSC.
RTRV-EQPT::SWC-8;
If yes, go to step 33.
If no, go to step 42.
If yes, go to step 34.
If no, go to step 42.
to retrieve DCC.
RTRV-EQPT::DCC-7;
to retrieve other DCC.
RTRV-EQPT::DCC-8;
If yes, go to step 38.
If no, go to step 42.