TAP-118
Are there any source reference alarms on sync referenced facilities or equipment?
9
Clear these alarms first. Refer to IXL-101.
10
11
CAUTION: Possibility of service interruption. Follow procedure in
CLK unit to avoid interrupting service.
Replace standby TC. Refer to DLP-137.
12
Enter
13
Did alarm clear?
14
Replace other TC. Refer to DLP-137.
15
Enter
16
Did alarm clear?
17
Contact next level of technical support for assistance.
18
19
STOP. This procedure is complete.
4-58
If yes, go to step 10.
If no, go to step 11.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 19.
If no, go to step 15.
and
RTRV-ALM-ALL;
RTRV-COND-ALL;
If yes, go to step 19.
If no, go to step 18.
3EM13853AF
Issue 01, September 2007
DLP-137
when replacing
HLD Alarm